A sensor resting on the thigh reads how much oxygen is left in the working muscle, and adds a vantage point to heart rate that the heart itself can never have.
- What SmO2 measures, and how light passing through the skin manages to measure it
- How data from the heart differs from data from a single muscle
- Two practical examples: a climb at a steady pace and the rest between intervals
- The limits of a tool still in development
- What has surfaced so far about what’s coming to watches
Heart rate is your home’s main electric meter. It tells you how much power the whole building is drawing, but not which room just switched on a space heater. For years, that was enough for runners: watches are hardly short on numbers, from pace to estimated aerobic fitness, and heart rate ties them all together. Lately, though, another acronym keeps coming up among runners who train by the data. It’s SmO2, and it offers something the meter can’t do: walk into a single room and see what’s going on in there.
What Is SmO2 and How Is It Measured
SmO2, short for muscle oxygen saturation, is the percentage of hemoglobin in a muscle that is still carrying oxygen. Hemoglobin is the blood protein that picks up oxygen in the lungs and delivers it to the tissues. Loaded or depleted, it absorbs light differently, and the whole measurement rests on that difference.
The sensor is a small rectangle fixed to the skin over the muscle you want to watch: for runners, often the quadriceps. It sends out near-infrared light, invisible to the eye and able to pass through tissue, then collects what bounces back. From the ratio of loaded to depleted hemoglobin, it calculates a percentage. What it reads is the blood in the smallest vessels, capillaries included, which is the exact point where oxygen passes from the blood into the muscle.
What It Shows That Heart Rate Doesn’t
The heart responds to the whole body at once. Speed up and it rises, slow down and it drops, but always with a lag, and always averaging everything: legs, arms, heat, stress. SmO2 looks into a single room and describes a balance between the oxygen arriving with the blood and the oxygen the muscle burns. As long as the two match, the curve stays flat. When demand outpaces delivery, it drops.
Take a climb run at a steady pace. Your heart rate creeps up and settles, and if that were all you watched, everything would look under control. The sensor on your thigh may be telling a different story. Your quads, asked to push far harder than on the flat, use more oxygen than they receive, and the curve falls. You’re reading fatigue in one part of the body as it builds, before it turns into heavy legs at the top. The main meter shows normal usage; in one room, the space heater is maxed out.
The most interesting part comes when you stop. Between intervals, heart rate comes down on its own schedule, while SmO2 rises as blood refills the muscle, and the speed of that rebound shows how quickly the muscle recharges. Two rest periods that look identical on your watch can hide very different recoveries: in one, the curve is back up before the next rep starts; in the other, it stalls halfway. We think this is the most valuable number for runners, because it makes visible something you could only feel in your legs until now: whether the rest was long enough.
How fast a muscle refills with oxygen is a useful marker of its ability to use it, which is why this data can sit alongside heart rate and power when you track a workout. Alongside is the key word. Reading one room only makes sense if you also know how much the whole house is drawing.
The Limits of a Young Measurement
The sensor reads the room through a wall. The layer of fat under the skin weakens the signal considerably, so two people working equally hard can see different curves just because their walls differ in thickness. How the sensor is attached matters too: a strap that’s too tight squeezes the vessels underneath and alters the very blood flow it’s trying to measure. On top of that, absolute values from different devices often can’t be compared, and researchers in the field are calling for standardization.
That’s why, for now, SmO2 works best as a comparison with yourself (same sensor, same spot, similar sessions) rather than as a number to hold up against a training partner’s. More precise devices are still missing, and so are studies that follow athletes over months instead of a single session. Anyone using it today is a pioneer, and should know it.
What We Know About What’s Coming to Watches
So far, very little, and what there is comes from leaks. In July, data fields showed up in the Garmin Connect app for oxygenated hemoglobin, with average, minimum, and maximum, and for total hemoglobin. In September, it came out that back in February Garmin had filed a trademark for “Muscle Battery”, described as an algorithm built on SmO2 data. No product announced, no release date. One detail helps put all this in perspective: SmO2 can’t be read from the wrist. It takes a sensor placed on the working muscle.